How do I reset the limits on a motorized screen?
To reset one limit on a motorized screen, send the screen to the limit that is wrong, put the motor into adjust mode, move the bar to the new stop and save it. On a Somfy Maestria 50 RTS you hold UP and DOWN until the screen jogs, move it, then hold MY until it jogs again. On a Rollease Acmeda Automate zip screen motor you hold UP and STOP (or DOWN and STOP) for about 5 seconds before and after the move. Mechanical-limit motors use a screw on the motor head. Two exceptions: a limit the motor found by itself cannot be nudged, so you redo the automatic setting, and a screen that stops in a different place each time usually has nothing wrong with its limits.
Key takeaways
- Know your system first: electronic limits set from the remote, automatic limits found against a hard stop, or mechanical screws on the motor head.
- Somfy's Maestria+ 50 io readjustment steps "apply only for end limits that are set manually."
- The bottom limit goes where the seal is compressed but the bar is not resting on the sill. On a Rollease Acmeda Ultra-Lock screen, after both lock pins click.
- Somfy rates Sunea Screen 40 io limits at ±5° of rotation, about ±4 mm (5/32 in) of bar travel. A bar that misses by an inch has slipped, hit something or overheated.
- A factory reset erases the limits and every paired remote. Leave it until last.
Is it really the limits?
A wrong limit stops the screen in the same wrong place every time. If the stop moves around, look elsewhere first.
| What the screen does | Most likely cause | What to do |
|---|---|---|
| Stops at the same wrong height every time | Limit set in the wrong place | Readjust that limit (below) |
| Bar sits on the sill, fabric slack and wavy | Bottom limit too low | Raise the bottom limit |
| Stops too soon even after the limits are reset | Limit ring (crown) not correctly installed | Installer refits the ring, then reset limits |
| Stops partway and backs up | Obstacle detection, often a bar dragging in a channel | Clear the channels, check bar clearance |
| Stops after several runs, works again later | Thermal cutout | Let it cool; Isotra says half an hour |
| Jogs when pressed but does not travel | Motor left in programming mode, or limits erased | Finish or restart the setting sequence |
| Runs past its stop on a shared switch | Several wired motors on one switch, no relay box | Fit a relay box |
Somfy's Maestria+ 50 io instructions (2015) give two causes for a screen that "stops too soon": the ring "is not correctly installed," or the end limits "are incorrectly programmed." Isotra's HR10-ZIP zip screen manual (2022) blames a motor that "does not stop in time" on "faulty adjustment of limit switches," and warns that several Somfy LT or LS motors on one switch without a relay box will soon burn out their integral limit switches. Somfy's LT 50 CSI instructions say: "Never connect two motors to a single control point."
If the screen does not move at all, start with power, the remote battery and sensor lockouts in retractable screen repair. If it ignores one remote, see remote not working; the pairing steps apply to screen motors on the same radio systems.
Which limit system does your screen have?
Read the label on the motor head or the manual; motor choices for screens are in motorized patio screens. How a motor counts its way to a stop is explained in tubular motor internals.
| Motor | How limits are set | Readjust one limit | Catch |
|---|---|---|---|
| Somfy Maestria 50 RTS | Manual, semi-automatic (auto top) or automatic | Send to limit, hold UP + DOWN until it jogs, move, hold MY until it jogs | Automatic top limit only "with screens featuring a hard stop" |
| Somfy Maestria+ 50 io | Five modes (E1-E5), chosen by top stop, bottom catches and heavy bar | Send to limit, hold UP + DOWN 5 s, move, hold MY | Only for limits set manually |
| Rollease Acmeda Automate (Zipscreen) | Step mode at first setup | Hold UP + STOP (or DOWN + STOP) about 5 s, move, hold again to save | Ultra-Lock bottom limit between lock and unlock |
| Automate motors on an ARC remote | Preset at installation | Hold UP + STOP until one jog, move, hold until two jogs (DOWN + STOP for the bottom) | Remote must be unlocked |
| Mechanical limit motors (wired switch) | Screw or push button per direction on the motor head | Run to the stop, turn the screw toward "+" for more travel | Head must be reachable |
Sources: Somfy's Maestria 50 RTS quick programming guide (October 2018), the io instructions, Rollease Acmeda's Zipscreen installation manual (v4.4, March 2020) and Automate's limit adjustment article, which does not say which motors it covers. Simu's T5 ZSP manual describes its setting type 3 in the same words Somfy uses for automatic mode: "especially suitable for ZIP screens with a heavy load bar and a top stop."
Somfy Maestria 50 RTS: readjust a limit
This is the user-mode adjustment from Somfy's guide. The remote must already be paired, and the other limit is left alone.
- Go to the wrong limit. Press DOWN (or UP) and let the screen stop at its current limit.
- Enter adjust mode. Hold UP and DOWN together until the screen jogs (a short up-and-down movement).
- Move to the new stop. Use short presses of UP or DOWN. Watch the bar, not the remote.
- Save. Hold MY until the screen jogs.
- Test. Run the screen fully up and down and check both stops.
In programming mode, Somfy allows 2 seconds between presses and exits after 2 minutes without input, so if the screen stops responding, start again. Check direction too: if UP and DOWN are reversed, Somfy warns an Eolis or Soliris RTS sensor "will not function in the manner it was intended," risking damage or injury. RTS and io are compared in the Somfy motors guide. Limits are set on the motor, never in a hub app: an RTS motor sends nothing back, so a hub only knows the last command, as explained in Bond Bridge Pro vs Somfy TaHoma.
Somfy Maestria+ 50 io: automatic limits
Its automatic mode (E3) is "especially suitable for ZIP screens." Start halfway, briefly press UP and DOWN together, then press DOWN. The screen "lowers until it detects the lower end limit, performs a brief upward movement and returns," and you confirm with MY. If that fails "after several attempts," Somfy says to use E2: set the lower limit by hand and let the motor find the upper one. Manually set limits are readjusted like RTS, but with a 5-second hold. Automatic limits are changed only by repeating the automatic setting.
Rollease Acmeda Automate zip screens
The Zipscreen manual says to cycle the screen "up and down prior to setting limits to settle fabric." Later changes follow its Part L:
- Upper limit. Hold UP and STOP for about 5 seconds until the motor responds, run to the new top and hold UP and STOP again. The manual's top limit is "as close to the box as possible."
- Lower limit. Hold DOWN and STOP for about 5 seconds, jog down until both lock pins click, then hold DOWN and STOP. The limit must sit "between the locking & unlocking position."
- Activate fabric tension mode. On Ultra-Lock screens, DOWN then lowers to the limit and tensions the fabric.
Automate's article adds that the remote must be unlocked (on the 15-channel remote, hold P2 until the display flashes "U") and that grouped channels cannot change limits. Rollease Acmeda's remote programming guide warns that holding UP or DOWN for more than 3 seconds may overshoot, and advises 1-second presses.
Mechanical limit screws
Hardwired screens on a wall switch often have one adjuster per direction on the motor head. Nice's Era instructions say to run the motor to its factory stop, then "gradually turn the adjustment screw" toward the "+" sign until it reaches the stop you want. For the other end, first back that screw off a few turns toward "–." Which screw is which depends on the motor's side and whether the fabric hangs in front of or behind the roller. Go a little at a time: Isotra warns the lower end position "must never be exceeded," as it "could lead to reverse winding of the fabric."
Where the bottom limit belongs
Isotra lists a lower limit set "too low or too loosely" among the causes of slack fabric. Rollease Acmeda sets the bottom "to the lowest point possible" with the seal "compressed as much as possible." Both hold if the bar stops with its seal squeezed, before the sill takes its weight. Slack fabric shows as waves; see zip screen wrinkles. On a sloped patio the bar touches the high side first, and lowering the limit cannot close the gap at the low side; see gaps under a motorized screen on a sloped floor.
Rollease Acmeda traces a screen that "gets jammed half way down" to the bar end cap hitting the rail, and wants about 3 mm (0.12 in) of gap. That looks like a limit fault but is a fit problem; alignment is covered in installing motorized patio screens.
Factory reset: the last resort
Somfy's io manual warns a reset "deletes all programmed control points, sensors and end limit settings." With the screen halfway, cut power for 2 seconds, restore it for 5-15 seconds, cut it for 2 seconds and restore it, then hold PROG until the screen moves up and down twice. The RTS guide shows 8 seconds between cuts and a PROG hold of about 7 seconds. Cut power only to the motor being reset, then set direction, limits and remotes from scratch.
Somfy writes these steps for installers. A limit nudge from the remote is a homeowner job; opening the box, refitting a ring or rewiring a switch is the installer's, and may be a warranty question (see retractable screen warranties).
Where this stops applying
- Sequences are model-specific. These are the manuals we read; the label on your motor decides which applies. Battery and DC motors have their own guides.
- A screen that drops in wind or leaves its channel has a different problem; see screen off track.
Bottom line
Send the screen to the bad limit, enter adjust mode (UP + DOWN on Somfy, UP or DOWN + STOP on Automate), move in short presses, save. Put the bottom limit where the seal is compressed but the bar hangs free of the sill. If the motor set the limit itself, redo the automatic setting. If the stop drifts, fix the cause first.
Frequently asked questions
Why did my screen lose its limits after a power outage?
Limits are stored in the motor. But a supply that cuts out twice in quick succession follows the double power cut pattern and can put the motor into programming mode. If it jogs and will not travel, restart the setting sequence.
My screen stops short some days and not others. Is that the limit?
Probably not; a limit repeats within millimeters. Look for a dragging bar or debris triggering obstacle detection. Rollease Acmeda also notes a gust adds rail friction and can stop the bar for a moment.
Sources and standards consulted
- Tubular motor troubleshooting, limit-setting and remote pairing guides (manufacturer documentation)
- Lateral arm awning service manuals (pitch, arm and spring adjustment) (manufacturer documentation)
- Retractable screen manufacturer service and re-tensioning instructions (manufacturer documentation)
See how we research for our sourcing and verification process.