The gap is there because the screen is level and the patio is not. The bottom bar of a motorized screen is rigid and hangs parallel to a head box mounted dead level, while a patio is poured with a slope so rain runs off. The bar stops when it touches the high side, and the low side stays open by the slope times the width: 1/8 in per foot over a 12 ft screen leaves a 1-1/2 in (38 mm) wedge. Close it by changing how the bar meets the floor (a brush, an angled bar, a floating bar or a level sill), not by running the motor further down.
Key takeaways
- Gap at the low end = floor slope (in per ft) x screen width (ft). Drainage slopes of 1/8-1/4 in per ft give 1-4 in (25-102 mm) over 8-16 ft.
- Screens that run down the slope, usually the side screens of a patio, take the full gap. A front screen parallel to the house may barely see it.
- A brush on the bar covers about the first 3/4 in. Draper's floating Align Bar covers "slope gaps up to 4" (102 mm) over a maximum length of 16'".
- Do not lower the bottom limit to close the gap. The bar already sits on the high side; the fabric goes slack and the gap stays.
Why a level screen leaves a gap on a sloped floor
Zip screens are installed to level, not to the floor. Isotra's Screen HR10-ZIP manual (valid from 12.9.2022) says to "make sure that the screens are always dead level and installed perfectly square." The bottom bar (bottom lath, weight bar or hem bar, depending on the maker) hangs parallel to the box and does not bend to follow a floor.
The patio is sloped on purpose. Tucson Rolling Shutters' patent for a self-adjusting bottom bar, US10934772B2 (filed February 19, 2018), starts from the problem: "patios typically use a slightly sloped floor to shed water," and with installations "in excess of 10 feet being common," this "can result in substantial floor gaps of one inch or more from end-to-end." Its continuation, US11585151B2, names the cost: the gap lets "pests to come into the screened space underneath the base bar."
Rollease Acmeda's Zipscreen installation manual (v4.4, March 2020) builds the gap into its measuring rules. With the top level, the two drop measurements "will not be equal as there is an uneven ground," and the shorter one sets the size: "Ensure the smallest value of D1 & D2 = Blind Drop." The base of the side guides "should not be lower than the measured highest point" on the floor. A correctly built screen is sized to the high point.
How big the gap is: slope x width
Multiply the slope along the screen, in inches per foot, by the screen width in feet. A 1% slope is about 1/8 in per ft (0.12 in); 2% is about 1/4 in per ft.
| Screen width | 1/8 in per ft (about 1%) | 3/16 in per ft (about 1.6%) | 1/4 in per ft (about 2%) |
|---|---|---|---|
| 6 ft (1.83 m) | 3/4 in (19 mm) | 1-1/8 in (29 mm) | 1-1/2 in (38 mm) |
| 8 ft (2.44 m) | 1 in (25 mm) | 1-1/2 in (38 mm) | 2 in (51 mm) |
| 10 ft (3.05 m) | 1-1/4 in (32 mm) | 1-7/8 in (48 mm) | 2-1/2 in (64 mm) |
| 12 ft (3.66 m) | 1-1/2 in (38 mm) | 2-1/4 in (57 mm) | 3 in (76 mm) |
| 14 ft (4.27 m) | 1-3/4 in (44 mm) | 2-5/8 in (67 mm) | 3-1/2 in (89 mm) |
| 16 ft (4.88 m) | 2 in (51 mm) | 3 in (76 mm) | 4 in (102 mm) |
Direction matters as much as slope. A patio drains away from the house, so a screen across the front edge, parallel to the house, has the slope running under it front to back and may land almost evenly. A screen on either side runs down the slope and takes the whole table value, the same point made for porch bays in porch and lanai screen enclosures. Measure every opening anyway.
First, make sure it is the floor
A crooked-looking bar is not always a sloped floor. Rollease Acmeda's fault table gives "Box is not level, thus weight bar appears uneven" as the first cause of an uneven weight bar, and Isotra puts a bottom lath "slanted at the top" down to guide rails that "run parallel but not perpendicular to the box." Three checks sort it out:
- Level on the head box. If the box is out, the bar follows it. Re-level the box; the floor may be fine.
- Level on the bottom bar, screen fully down. If the box is level and the bar is not, the channels are not square to the box. Measure widths and diagonals as in zip screen wrinkles (Isotra's limit is 2 mm); channel types are in screen tracks and guide rails.
- Level on the floor under the bar. If box and bar are level and the floor is not, the gap is slope. Measure it at both channels and pick a fix below.
The four fixes and how much each covers
| Fix | How it closes the gap | Range in the sources read | Catch |
|---|---|---|---|
| Brush (pile) seal on the bar | Bristles reach down to the floor | Common pile heights to 0.75 in (19 mm); aprons "of up to an inch or more" on uneven floors (patent) | The patent calls such aprons "unsightly" and says they gather "dust and debris" |
| Angled bottom bar | The bar is set at the deck's slope, so it lands along its length | Not stated | Built for one slope; the bar looks slanted in the frame |
| Floating bar | A second bar under the hem bar tilts until its whole length rests on the floor | Draper Align Bar: up to 4 in (102 mm) over 16 ft (4.88 m). Patent design: 1.5 in pivot at either end | Draper's fits FlexShade ZIP only; the pivoting arm is a patent, not a catalog part |
| Level sill or tapered threshold | A strip on the slab gives the bar a level landing | Any gap | As tall as the gap at the low end: a step to trip over |
Brush seal: up to about 3/4 in
A pile strip in the bar is the standard bottom seal, and on a nearly flat floor it is all you need. The tallest pile in our brush seal and pile size guide is 0.300-0.750 in (7.6-19 mm), sold for large sweeps and garage screens. That covers a 6 ft screen at 1/8 in per ft, or the small cross-fall under a front screen. Past that, the patent's verdict on bristle or felt aprons applies: they are "unsightly, gathers dust and debris, and for some substantially uneven floors, 'cat hair' aprons of up to an inch or more are required."
Angled bottom bar: for one known slope
Some builders set the bottom bar at the slope of the deck instead of level. Suncoast Enclosures explains its slanted bars in why does my screen not look level: "The design allows the screen to align with the slope of the deck, ensuring a proper seal when closed." On a sloped deck the result is "a more angled bottom bar." The angle suits one measured slope, and Suncoast's page gives no maximum; ask the maker.
Floating bar: for the big gaps
A floating bar keeps the hem bar level for the fabric and adds a member underneath that is free to follow the floor. Draper's Align Bar is an extruded aluminum bar that encapsulates the standard FlexShade ZIP hem bar and "covers slope gaps up to 4" (102 mm) over a maximum length of 16' (4.88 m)": the 1/4 in per ft corner of the table, the steep end of the usual drainage range. It has "black brush liners on the bottom edge and endcaps," a 5.17 x 1.31 in (131.3 x 33.3 mm) profile, and can be retrofitted to existing ZIP screens up to 16 ft wide. Draper's ZIP housings are compared with others in motorized screen housing sizes.
The Tucson Rolling Shutters patents pivot instead. An adjustable arm "protrudes from the hollow bar by a predetermined amount, in one embodiment, by 0.75″" and hangs from a central pivot, "enabling pivoting displacement of 1.5 inches at either end." The continuation adds 0.25 in of vertical travel. These are patent figures, not a product rating.
Level sill or tapered threshold: any gap, one more step
The other answer is to change the floor. A tapered strip fixed to the slab under the screen line, zero at the high end and as tall as the gap at the low end, gives a standard bar a level landing. On a walk-through opening the low end is a step the height of the gap: 3 in on a 12 ft screen at 1/4 in per ft. Fix the landing before the bottom limit is set, as in the porch example in installing motorized patio screens.
Why lowering the bottom limit makes it worse
Driving the bar further down cannot work: the bar is rigid and already touching the high side. Isotra's fault list for slack fabric names both halves of that mistake: a bottom lath "not suspended properly from the fabric" but resting on the sill, and a lower end limit set too low or "too loosely." The gap stays the same size, and the fabric now waves (see zip screen wrinkles).
The bottom limit belongs where the seal is compressed at the high end and the bar still hangs from the fabric. How to move it is in how to reset the limits on a motorized screen. After fitting a floating bar or a sill strip, reset it, because the landing has moved.
Where this stops applying
- Gaps over 4 in. That is past the largest published range we found (Draper's, over 16 ft). Split the opening into narrower screens or change the floor.
- Humped or dished floors. The arithmetic assumes a straight slope. A high point mid-span leaves gaps at both ends, and a bar pivoting in the middle is made for a straight slope.
- Cable-guided screens. The arithmetic is the same, but the floating bar figures above are for zip screens (edge systems are compared in zip track, keder and zipper edges).
Bottom line
Measure the drop at each channel; the difference is your gap, about slope x width. Up to about 3/4 in, a brush closes it. A known larger slope can be built in with an angled bar. Up to 4 in over 16 ft, a floating bar such as Draper's Align Bar follows the floor. Past that, level the landing. Never lower the bottom limit to chase the gap.
Frequently asked questions
Is a gap under my new motorized screen an installation fault?
Not by itself. Rollease Acmeda sizes the drop to the high point of the floor, so a level screen over a sloped patio leaves a gap at the low end by design. The fault is a gap with no seal plan, or a bar out of level because the box is.
Sources and standards consulted
- Tubular motor troubleshooting, limit-setting and remote pairing guides (manufacturer documentation)
- Lateral arm awning service manuals (pitch, arm and spring adjustment) (manufacturer documentation)
- Retractable screen manufacturer service and re-tensioning instructions (manufacturer documentation)
See how we research for our sourcing and verification process.